1. Physical Properties
| Property | Metric / Source Value | US / International Equivalent |
|---|---|---|
| Density | 5.6 g/cm³ | ≈ 0.202 lb/in³ |
| Flexural Strength | ≥ 1.5 kg/cm² | ≈ ≥ 21.3 psi* |
| Vickers Hardness (20°C) | 1200 kg/cm² | ≈ 17,068 psi* |
| Porosity | 7.4% | 7.4% |
| Water Absorption | 1.2% | 1.2% |
| Thermal Elongation | 4% – 5% | 4% – 5% |
*US customary equivalents for the strength values use the kgf/cm² conversion because the supplied source writes the unit as kg/cm².
The elements are hard and brittle at room temperature and have low flexural strength. When the element temperature exceeds 1350°C, the supplied specification states that it undergoes plastic softening and can be bent into desired shapes.
2. Chemical Properties & Maximum Operating Temperatures
When heated to high temperatures in an oxidizing atmosphere, a dense protective SiO₂ layer forms on the element surface and prevents further oxidation. The supplied specification states that extended operation in the 400–700°C range should be avoided because low-temperature oxidation can occur.
| Furnace Atmosphere | Maximum Operating Temperature (°C) | Maximum Operating Temperature (°F) |
|---|---|---|
| NO₂, CO₂, O₂, Air | 1800°C | 3272°F |
| He, Ar, Ne | 1750°C | 3182°F |
| SO₂ | 1700°C | 3092°F |
| CO, N₂ | 1600°C | 2912°F |
| Wet H₂ | 1500°C | 2732°F |
| Dry H₂ | 1450°C | 2642°F |
3. Electrical Resistance Characteristics
The supplied specification states that the electrical resistance of MoSi₂ heating elements increases rapidly as temperature rises. When temperature remains constant, resistance acts as a constant value. Under normal operating conditions, resistance generally does not change with duration of use, so new and old elements can be mixed and used together in the same circuit.
4. Installation & Operation Guidelines
Surface Load Selection
Correctly choosing the element surface load according to furnace structure, atmosphere and temperature is stated as essential for maximum element life. Standard operating configurations follow the designated heat-dissipation limits.
Mechanical Installation
Products are generally manufactured as U-types and installed vertically hanging. The conical portion must fully extend into the furnace chamber. Cold-end clamps should not be overtightened at the start; secondary tightening is performed after the elements reach high temperature.
Clearances & Electrical Safety
Element-to-hearth distance: ≥25 mm (≈0.98 in). Furnace roof temperature: generally ≤300°C (≤572°F). Contact voltage between clamp lead and element: <0.1 V. Lower clamp edge to top of insulating plug brick: ≥50 mm (≈1.97 in).
Amperage Limits
| Element Size | Continuous Current Limit — Source Guideline |
|---|---|
| Φ6/12 mm (≈0.24/0.47 in) | Should not be operated continuously at 170 A |
| Φ9/18 mm (≈0.35/0.71 in) | Should not be operated continuously at 300 A |
5. Step-Down Voltage Power Supply
| Furnace Type / Power Status | Temperature (°C) | Temperature (°F) | Applied Voltage |
|---|---|---|---|
| Small-scale Furnaces (< 100 kW) | 20°C – 150°C | 68°F – 302°F | 1/3 of Full Working Voltage |
| Small-scale Furnaces (< 100 kW) | 150°C – 500°C | 302°F – 932°F | 1/2 of Full Working Voltage |
| Small-scale Furnaces (< 100 kW) | 500°C – Operating Temperature | 932°F – Operating Temperature | Full Working Voltage |
| Large-scale Furnaces (100 – 500 kW) | 200°C – 300°C | 392°F – 572°F | 1/3 of Full Working Voltage |
| Large-scale Furnaces (100 – 500 kW) | 300°C – 700°C | 572°F – 1292°F | 1/2 of Full Working Voltage |
| Large-scale Furnaces (100 – 500 kW) | 700°C – Operating Temperature | 1292°F – Operating Temperature | Full Working Voltage |
6. Grade 1700 U-Type — 6/12 mm Complete Lookup Table
Standard test conditions: Element Temperature = 1500°C (2732°F) | Furnace Temperature = 1300°C (2372°F) | Amperage = 150 A | Surface Load = 15 W/cm² (≈96.77 W/in²).
| Hot End Length Le mm / in | Cold End Length Lc mm / in | Power W | Electrical Resistance Ω | Working Voltage V |
|---|---|---|---|---|
| 150 mm 5.91 in | 150 mm 5.91 in | 987 W | 0.044 Ω | 6.6 V |
| 150 mm 5.91 in | 180 mm 7.09 in | 1152 W | 0.051 Ω | 7.7 V |
| 150 mm 5.91 in | 200 mm 7.87 in | 1262 W | 0.056 Ω | 8.4 V |
| 150 mm 5.91 in | 250 mm 9.84 in | 1538 W | 0.068 Ω | 10.2 V |
| 150 mm 5.91 in | 300 mm 11.81 in | 1810 W | 0.080 Ω | 12.1 V |
| 150 mm 5.91 in | 350 mm 13.78 in | 2084 W | 0.093 Ω | 13.9 V |
| 200 mm 7.87 in | 150 mm 5.91 in | 1025 W | 0.046 Ω | 6.8 V |
| 200 mm 7.87 in | 180 mm 7.09 in | 1189 W | 0.053 Ω | 7.9 V |
| 200 mm 7.87 in | 200 mm 7.87 in | 1299 W | 0.058 Ω | 8.7 V |
| 200 mm 7.87 in | 250 mm 9.84 in | 1573 W | 0.070 Ω | 10.5 V |
| 200 mm 7.87 in | 300 mm 11.81 in | 1848 W | 0.082 Ω | 12.3 V |
| 200 mm 7.87 in | 350 mm 13.78 in | 2122 W | 0.094 Ω | 14.1 V |
| 200 mm 7.87 in | 400 mm 15.75 in | 2396 W | 0.106 Ω | 16.0 V |
| 250 mm 9.84 in | 150 mm 5.91 in | 1062 W | 0.047 Ω | 7.1 V |
| 250 mm 9.84 in | 180 mm 7.09 in | 1227 W | 0.055 Ω | 8.2 V |
| 250 mm 9.84 in | 200 mm 7.87 in | 1337 W | 0.059 Ω | 8.9 V |
| 250 mm 9.84 in | 250 mm 9.84 in | 1611 W | 0.072 Ω | 10.7 V |
| 250 mm 9.84 in | 300 mm 11.81 in | 1885 W | 0.084 Ω | 12.6 V |
| 250 mm 9.84 in | 350 mm 13.78 in | 2159 W | 0.096 Ω | 14.4 V |
| 250 mm 9.84 in | 400 mm 15.75 in | 2434 W | 0.108 Ω | 16.2 V |
| 250 mm 9.84 in | 450 mm 17.72 in | 2708 W | 0.120 Ω | 18.1 V |
| 300 mm 11.81 in | 150 mm 5.91 in | 1100 W | 0.049 Ω | 7.3 V |
| 300 mm 11.81 in | 180 mm 7.09 in | 1264 W | 0.056 Ω | 8.4 V |
| 300 mm 11.81 in | 200 mm 7.87 in | 1374 W | 0.061 Ω | 9.2 V |
| 300 mm 11.81 in | 250 mm 9.84 in | 1648 W | 0.073 Ω | 11.0 V |
| 300 mm 11.81 in | 300 mm 11.81 in | 1923 W | 0.085 Ω | 12.8 V |
| 300 mm 11.81 in | 350 mm 13.78 in | 2197 W | 0.098 Ω | 14.6 V |
| 300 mm 11.81 in | 400 mm 15.75 in | 2471 W | 0.110 Ω | 16.5 V |
| 300 mm 11.81 in | 450 mm 17.72 in | 2745 W | 0.122 Ω | 18.3 V |
| 300 mm 11.81 in | 500 mm 19.69 in | 3019 W | 0.134 Ω | 20.1 V |
7. Grade 1700 U-Type — 9/18 mm Complete Lookup Table
Standard test conditions: Element Temperature = 1500°C (2732°F) | Furnace Temperature = 1300°C (2372°F) | Amperage = 275 A | Surface Load = 14.5 W/cm² (≈93.55 W/in²).
| Hot End Length Le mm / in | Cold End Length Lc mm / in | Power W | Electrical Resistance Ω | Working Voltage V |
|---|---|---|---|---|
| 150 mm 5.91 in | 150 mm 5.91 in | 1598 W | 0.021 Ω | 5.8 V |
| 150 mm 5.91 in | 180 mm 7.09 in | 1841 W | 0.024 Ω | 6.7 V |
| 150 mm 5.91 in | 200 mm 7.87 in | 2003 W | 0.027 Ω | 7.3 V |
| 150 mm 5.91 in | 250 mm 9.84 in | 2414 W | 0.032 Ω | 8.8 V |
| 150 mm 5.91 in | 300 mm 11.81 in | 2822 W | 0.037 Ω | 10.2 V |
| 150 mm 5.91 in | 350 mm 13.78 in | 3231 W | 0.043 Ω | 11.7 V |
| 150 mm 5.91 in | 400 mm 15.75 in | 3640 W | 0.048 Ω | 13.2 V |
| 180 mm 7.09 in | 150 mm 5.91 in | 1653 W | 0.022 Ω | 6.0 V |
| 180 mm 7.09 in | 180 mm 7.09 in | 1899 W | 0.025 Ω | 6.9 V |
| 180 mm 7.09 in | 200 mm 7.87 in | 2062 W | 0.027 Ω | 7.5 V |
| 180 mm 7.09 in | 250 mm 9.84 in | 2471 W | 0.033 Ω | 9.0 V |
| 180 mm 7.09 in | 300 mm 11.81 in | 2880 W | 0.038 Ω | 10.5 V |
| 180 mm 7.09 in | 350 mm 13.78 in | 3289 W | 0.044 Ω | 12.0 V |
| 180 mm 7.09 in | 400 mm 15.75 in | 3697 W | 0.049 Ω | 13.4 V |
| 200 mm 7.87 in | 150 mm 5.91 in | 1711 W | 0.023 Ω | 6.2 V |
| 200 mm 7.87 in | 180 mm 7.09 in | 1956 W | 0.026 Ω | 7.1 V |
| 200 mm 7.87 in | 200 mm 7.87 in | 2120 W | 0.028 Ω | 7.7 V |
| 200 mm 7.87 in | 250 mm 9.84 in | 2528 W | 0.033 Ω | 9.2 V |
| 200 mm 7.87 in | 300 mm 11.81 in | 2937 W | 0.039 Ω | 10.7 V |
| 200 mm 7.87 in | 350 mm 13.78 in | 3346 W | 0.044 Ω | 12.2 V |
| 200 mm 7.87 in | 400 mm 15.75 in | 3755 W | 0.050 Ω | 13.7 V |
8. Unit Conversion Reference
| Metric Unit | US / International Unit | Conversion Used |
|---|---|---|
| 1 mm | 0.0393701 in | in = mm ÷ 25.4 |
| 1 cm² | 0.155000 in² | in² = cm² × 0.155000 |
| 1 W/cm² | 6.4516 W/in² | W/in² = W/cm² × 6.4516 |
| °F | °C conversion | °F = °C × 9/5 + 32 |
| W | W | No conversion required |
| V | V | No conversion required |
| Ω | Ω | No conversion required |
| A | A | No conversion required |
| kW | kW | No conversion required |
9. Custom Manufacturing
MoSi₂ heating elements can be manufactured in different shapes and according to customer requirements. For quotation, please provide element type/shape, diameter, hot-zone length, cold-end dimensions, overall length, furnace temperature, atmosphere, quantity and electrical requirements where available.