SiC Heating Elements • Silicon Carbide Heating Rods Custom Specifications • Worldwide Export
SiC Heating Elements • Silicon Carbide Heating RodsCustom Specifications • Worldwide Export

MoSi₂ Heating Elements — Complete Technical Data

Molybdenum disilicide (MoSi₂) heating elements for high-temperature industrial furnaces and thermal equipment. This page presents the supplied technical specification in English, with metric units and US customary conversions for international customers.

Grade 1700 U-Type6/12 mm9/18 mmCustom Manufacturing

1. Physical Properties

PropertyMetric / Source ValueUS / International Equivalent
Density5.6 g/cm³≈ 0.202 lb/in³
Flexural Strength≥ 1.5 kg/cm²≈ ≥ 21.3 psi*
Vickers Hardness (20°C)1200 kg/cm²≈ 17,068 psi*
Porosity7.4%7.4%
Water Absorption1.2%1.2%
Thermal Elongation4% – 5%4% – 5%

*US customary equivalents for the strength values use the kgf/cm² conversion because the supplied source writes the unit as kg/cm².

The elements are hard and brittle at room temperature and have low flexural strength. When the element temperature exceeds 1350°C, the supplied specification states that it undergoes plastic softening and can be bent into desired shapes.

2. Chemical Properties & Maximum Operating Temperatures

When heated to high temperatures in an oxidizing atmosphere, a dense protective SiO₂ layer forms on the element surface and prevents further oxidation. The supplied specification states that extended operation in the 400–700°C range should be avoided because low-temperature oxidation can occur.

Furnace AtmosphereMaximum Operating Temperature (°C)Maximum Operating Temperature (°F)
NO₂, CO₂, O₂, Air1800°C3272°F
He, Ar, Ne1750°C3182°F
SO₂1700°C3092°F
CO, N₂1600°C2912°F
Wet H₂1500°C2732°F
Dry H₂1450°C2642°F

3. Electrical Resistance Characteristics

The supplied specification states that the electrical resistance of MoSi₂ heating elements increases rapidly as temperature rises. When temperature remains constant, resistance acts as a constant value. Under normal operating conditions, resistance generally does not change with duration of use, so new and old elements can be mixed and used together in the same circuit.

4. Installation & Operation Guidelines

Surface Load Selection

Correctly choosing the element surface load according to furnace structure, atmosphere and temperature is stated as essential for maximum element life. Standard operating configurations follow the designated heat-dissipation limits.

Mechanical Installation

Products are generally manufactured as U-types and installed vertically hanging. The conical portion must fully extend into the furnace chamber. Cold-end clamps should not be overtightened at the start; secondary tightening is performed after the elements reach high temperature.

Clearances & Electrical Safety

Element-to-hearth distance: ≥25 mm (≈0.98 in). Furnace roof temperature: generally ≤300°C (≤572°F). Contact voltage between clamp lead and element: <0.1 V. Lower clamp edge to top of insulating plug brick: ≥50 mm (≈1.97 in).

Amperage Limits

Element SizeContinuous Current Limit — Source Guideline
Φ6/12 mm (≈0.24/0.47 in)Should not be operated continuously at 170 A
Φ9/18 mm (≈0.35/0.71 in)Should not be operated continuously at 300 A

5. Step-Down Voltage Power Supply

Furnace Type / Power StatusTemperature (°C)Temperature (°F)Applied Voltage
Small-scale Furnaces (< 100 kW)20°C – 150°C68°F – 302°F1/3 of Full Working Voltage
Small-scale Furnaces (< 100 kW)150°C – 500°C302°F – 932°F1/2 of Full Working Voltage
Small-scale Furnaces (< 100 kW)500°C – Operating Temperature932°F – Operating TemperatureFull Working Voltage
Large-scale Furnaces (100 – 500 kW)200°C – 300°C392°F – 572°F1/3 of Full Working Voltage
Large-scale Furnaces (100 – 500 kW)300°C – 700°C572°F – 1292°F1/2 of Full Working Voltage
Large-scale Furnaces (100 – 500 kW)700°C – Operating Temperature1292°F – Operating TemperatureFull Working Voltage
Critical operational note: Keep voltage-switching duration as short as possible. The supplied specification states that element temperature should generally not be allowed to drop by 300–400°C (540–720°F) during switching, otherwise an aggressive current surge and permanent electrical breakdown may occur.

6. Grade 1700 U-Type — 6/12 mm Complete Lookup Table

Standard test conditions: Element Temperature = 1500°C (2732°F) | Furnace Temperature = 1300°C (2372°F) | Amperage = 150 A | Surface Load = 15 W/cm² (≈96.77 W/in²).

Hot End Length Le
mm / in
Cold End Length Lc
mm / in
Power
W
Electrical Resistance
Ω
Working Voltage
V
150 mm
5.91 in
150 mm
5.91 in
987 W0.044 Ω6.6 V
150 mm
5.91 in
180 mm
7.09 in
1152 W0.051 Ω7.7 V
150 mm
5.91 in
200 mm
7.87 in
1262 W0.056 Ω8.4 V
150 mm
5.91 in
250 mm
9.84 in
1538 W0.068 Ω10.2 V
150 mm
5.91 in
300 mm
11.81 in
1810 W0.080 Ω12.1 V
150 mm
5.91 in
350 mm
13.78 in
2084 W0.093 Ω13.9 V
200 mm
7.87 in
150 mm
5.91 in
1025 W0.046 Ω6.8 V
200 mm
7.87 in
180 mm
7.09 in
1189 W0.053 Ω7.9 V
200 mm
7.87 in
200 mm
7.87 in
1299 W0.058 Ω8.7 V
200 mm
7.87 in
250 mm
9.84 in
1573 W0.070 Ω10.5 V
200 mm
7.87 in
300 mm
11.81 in
1848 W0.082 Ω12.3 V
200 mm
7.87 in
350 mm
13.78 in
2122 W0.094 Ω14.1 V
200 mm
7.87 in
400 mm
15.75 in
2396 W0.106 Ω16.0 V
250 mm
9.84 in
150 mm
5.91 in
1062 W0.047 Ω7.1 V
250 mm
9.84 in
180 mm
7.09 in
1227 W0.055 Ω8.2 V
250 mm
9.84 in
200 mm
7.87 in
1337 W0.059 Ω8.9 V
250 mm
9.84 in
250 mm
9.84 in
1611 W0.072 Ω10.7 V
250 mm
9.84 in
300 mm
11.81 in
1885 W0.084 Ω12.6 V
250 mm
9.84 in
350 mm
13.78 in
2159 W0.096 Ω14.4 V
250 mm
9.84 in
400 mm
15.75 in
2434 W0.108 Ω16.2 V
250 mm
9.84 in
450 mm
17.72 in
2708 W0.120 Ω18.1 V
300 mm
11.81 in
150 mm
5.91 in
1100 W0.049 Ω7.3 V
300 mm
11.81 in
180 mm
7.09 in
1264 W0.056 Ω8.4 V
300 mm
11.81 in
200 mm
7.87 in
1374 W0.061 Ω9.2 V
300 mm
11.81 in
250 mm
9.84 in
1648 W0.073 Ω11.0 V
300 mm
11.81 in
300 mm
11.81 in
1923 W0.085 Ω12.8 V
300 mm
11.81 in
350 mm
13.78 in
2197 W0.098 Ω14.6 V
300 mm
11.81 in
400 mm
15.75 in
2471 W0.110 Ω16.5 V
300 mm
11.81 in
450 mm
17.72 in
2745 W0.122 Ω18.3 V
300 mm
11.81 in
500 mm
19.69 in
3019 W0.134 Ω20.1 V

7. Grade 1700 U-Type — 9/18 mm Complete Lookup Table

Standard test conditions: Element Temperature = 1500°C (2732°F) | Furnace Temperature = 1300°C (2372°F) | Amperage = 275 A | Surface Load = 14.5 W/cm² (≈93.55 W/in²).

Hot End Length Le
mm / in
Cold End Length Lc
mm / in
Power
W
Electrical Resistance
Ω
Working Voltage
V
150 mm
5.91 in
150 mm
5.91 in
1598 W0.021 Ω5.8 V
150 mm
5.91 in
180 mm
7.09 in
1841 W0.024 Ω6.7 V
150 mm
5.91 in
200 mm
7.87 in
2003 W0.027 Ω7.3 V
150 mm
5.91 in
250 mm
9.84 in
2414 W0.032 Ω8.8 V
150 mm
5.91 in
300 mm
11.81 in
2822 W0.037 Ω10.2 V
150 mm
5.91 in
350 mm
13.78 in
3231 W0.043 Ω11.7 V
150 mm
5.91 in
400 mm
15.75 in
3640 W0.048 Ω13.2 V
180 mm
7.09 in
150 mm
5.91 in
1653 W0.022 Ω6.0 V
180 mm
7.09 in
180 mm
7.09 in
1899 W0.025 Ω6.9 V
180 mm
7.09 in
200 mm
7.87 in
2062 W0.027 Ω7.5 V
180 mm
7.09 in
250 mm
9.84 in
2471 W0.033 Ω9.0 V
180 mm
7.09 in
300 mm
11.81 in
2880 W0.038 Ω10.5 V
180 mm
7.09 in
350 mm
13.78 in
3289 W0.044 Ω12.0 V
180 mm
7.09 in
400 mm
15.75 in
3697 W0.049 Ω13.4 V
200 mm
7.87 in
150 mm
5.91 in
1711 W0.023 Ω6.2 V
200 mm
7.87 in
180 mm
7.09 in
1956 W0.026 Ω7.1 V
200 mm
7.87 in
200 mm
7.87 in
2120 W0.028 Ω7.7 V
200 mm
7.87 in
250 mm
9.84 in
2528 W0.033 Ω9.2 V
200 mm
7.87 in
300 mm
11.81 in
2937 W0.039 Ω10.7 V
200 mm
7.87 in
350 mm
13.78 in
3346 W0.044 Ω12.2 V
200 mm
7.87 in
400 mm
15.75 in
3755 W0.050 Ω13.7 V

8. Unit Conversion Reference

Metric UnitUS / International UnitConversion Used
1 mm0.0393701 inin = mm ÷ 25.4
1 cm²0.155000 in²in² = cm² × 0.155000
1 W/cm²6.4516 W/in²W/in² = W/cm² × 6.4516
°F°C conversion°F = °C × 9/5 + 32
WWNo conversion required
VVNo conversion required
ΩΩNo conversion required
AANo conversion required
kWkWNo conversion required
Data accuracy: The numerical specification tables on this page are transcribed from the uploaded technical source. No missing table values have been invented. The uploaded source currently contains the 6/12 mm rows through Le 300 mm / Lc 500 mm and the 9/18 mm rows through Le 200 mm / Lc 400 mm; if you have additional source rows, they can be appended without changing the existing values.

9. Custom Manufacturing

MoSi₂ heating elements can be manufactured in different shapes and according to customer requirements. For quotation, please provide element type/shape, diameter, hot-zone length, cold-end dimensions, overall length, furnace temperature, atmosphere, quantity and electrical requirements where available.